| INSAPFLEX |
|
ENGINEERING DATA ASSEMBLY LENGTH |
| How To Determine Correct Assembly Length |
![]() |
| For most assemblies, the
correct assembly length may be determined by direct measurement of the equipment or a drawing. Minimum bend radii as shown in the hose specification tables should be observed. Assemblies are measured to the end of the Seal. |
To determine the length of hose needed in making assemblies with permanent or reusable couplings, subtract Dimension "C" (Cut Off factor) for each coupling from the required overall assembly length. |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Remember that hydraulic hose under pressure will elongate up to 2% of its length or contract up to 4% depending on pressure, type and size. Sufficient allowance should be made to permit such changes in length. | ![]() |